Transmitter WAT 02


Download PDF

Transmitter

In case of connection of load cells with 4 wires, make a bridge between power supply+ … reference+ and power supply- … reference-

Download usage manual

Download installation and usage manual


Zoom Click to enlarge image

Transmitter WAT 02

Technical Specifications

Power supply24 V dc ± 15 %
Max power consumption3 W
IsolationClass III
Operating temperature-10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing
Storage temperature-20 / +60 °C
Overall dimensions76 x 90 x 65 mm /2.99 x 3.54 x 2.56 in (l x h x p)
MountingSupport DIN or OMEGA rail
Case materialPolyamide 6.6 UL 94V-0, self-extinguishing
ConnectionsRemovable screw terminals. Pitch screws terminal blocks 5.08 mm
Power supply load cells10 V dc / 120 mA (maximum 4 cells with 350 Ω in parallel) short circuit protection
Linearity0,02 % of full scale
Temperature deviation0,005 % of full scale/°C
Measuring range1 mV/V – 2 mV/V – 3 mV/V
Zero / FS CalibrationAdjustment zero & f. s. fine with 18-turn resistive trimmer, zero -8% to +3% f.s.; gain ± 5% f.s.
Analog integrator filterAdjustable w. single-turn trimmer
Filter response time10-90%: 5–250 ms; 4-20mA: 5 ms
Analog output in tension0 - 10 V
 Impedance≥ 10 kΩ
Analog output under current0 - 20 mA / 4 - 20 mA
 Impedance≤ 300 Ω
Conforms to standardsCompliance to EMC norms: EN61000-6-2, EN61000-6-3, Compliance electric safety: EN 61010-1
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeTerminal block MA 9P pitch 5.08
LengthND
1+24 Vcc (voltage supply)
2GND (voltage supply)
3+ Exc. Load cell
4- Exc. Load cell
5- Signal load cell
6+ signal load cell
7Current analog out 0-20mA/4-20mA
8- Analog out (current / voltage)
9Voltage Analog out 0-10Vcc
Connections  Transmitter WAT 02

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means